SCOTT SPECIALTY GASES INC -- PROPANE/CO/CO2/NITROGEN GAS -- 6830-00F039657
=====================  Product Identification  =====================

Product ID:PROPANE/CO/CO2/NITROGEN GAS
MSDS Date:08/31/1989
FSC:6830
NIIN:00F039657
=== Responsible Party ===
Company Name:SCOTT SPECIALTY GASES INC
Address:6141 EASTON RD
Box:310
City:PLUMSTEADVILLE
State:PA
ZIP:18949-0310
Country:US
Info Phone Num:215-766-8861
Emergency Phone Num:215-766-8861
CAGE:51847
=== Contractor Identification ===
Company Name:SCOTT SPECIALTY GASES
Address:6141 EASTON RD (6141 ROUTE 611)
Box:310
City:PLUMSTEADVILLE
State:PA
ZIP:18934
Country:US
Phone:215-766-8861/ FAX: 215-766-0416
CAGE:51847

=============  Composition/Information on Ingredients  =============

Ingred Name:PROPANE
CAS:74-98-6
RTECS #:TX2275000
Other REC Limits:1800 MG/CUM
OSHA PEL:1000 PPM
ACGIH TLV:SIMPLE ASPHYXIANT

Ingred Name:CARBON MONOXIDE
CAS:630-08-0
RTECS #:FG3500000
Fraction by Wt: 1-4%
Other REC Limits:50 PPM
OSHA PEL:55 MG/CUM
ACGIH TLV:57 MG/CUM

Ingred Name:CARBON DIOXIDE
CAS:124-38-9
RTECS #:FF6400000
Fraction by Wt: 6-12%
Other REC Limits:10000 PPM
OSHA PEL:5000 PPM
ACGIH TLV:9000 MG/CUM

Ingred Name:NITROGEN
CAS:7727-37-9
RTECS #:QW9700000
Fraction by Wt: BALANCE
OSHA PEL:NONE
ACGIH TLV:ASPHYXIANT

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:MIXTURE ACTS AS A SIMPLE ASPHYXIANT.
    CARBON MONOXIDE IS HIGHLY TOXIC & MAY BE FATAL. CARBON DIOXIDE AT
    HIGH CONCENTRATIONS IS DANGEROUS TO LIFE.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:ASPHYXIATION, RAPID RESPIRATION, MUSCULAR
    INCOORDINATION, FATIQUE, NAUSEA, VOMITING, UNCONSCIOUSNESS. CARBON
    MONOXIDE-SHORTNESS OF BREATH, HEADACHE, CONFUSION, NAUSEA,
    DIZZINESS, UNCONSCIOUSNESS. CARB ON DIOXIDE-LABORED BREATHING,
    POSSIBLE UNCONSCIOUSNESS.

=======================  First Aid Measures  =======================

First Aid:INHALATION: REMOVE TO FRESH AIR. GIVE CPR/OXYGEN IF
    NECESSARY. OBTAIN MEDICAL ATTENTION IN ALL CASES.

=====================  Fire Fighting Measures  =====================

Flash Point:NONFLAMMABLE
Extinguishing Media:USE WHAT IS APPROPRIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures:USE WATER SPRAY TO KEEP FIRE EXPOSED CYLINDERS
    COOL. WEAR SELF CONTAINED BREATHING APPARATUS & FULL PROTECTIVE
    CLOTHING.
Unusual Fire/Explosion Hazard:NONE

==================  Accidental Release Measures  ==================

Spill Release Procedures:VENTILATE AREA. REMOVE LEAKING CYLINDER TO
    EXHAUST HOOD/SAFE OUT OF DOORS AREA.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN A WELL VENTILATED AREA AWAY
    FROM SOURCES OF HEAT & IGNITION. DON'T DEFACE CYLINDERS/LABELS.
    MOVE CYLINDER W/ADEQUATE HAND TRUCK.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE A SELF CONTAINED BREATHING APPARATUS IN CASE
    OF EMERGENCY/NON ROUTINE USE.
Ventilation:GENERAL/LOCAL EXHAUST TO MEET TLV REQUIREMENTS
Eye Protection:SAFETY GLASSES
Other Protective Equipment:SAFETY SHOES
Supplemental Safety and Health

==================  Physical/Chemical Properties  ==================

Vapor Density:1-1.03
Appearance and Odor:COLORLESS W/NO ODOR

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
PROPANE-OXIDIZING AGENTS; CO2-ALKALINE MATEIRALS; NITROGEN-LITHIUM,
    NEODYMIUM, THALLIUM
Stability Condition to Avoid:HIGH TEMPERATURES & IGNITION SOURCES
Hazardous Decomposition Products:CARBONATES & BICARBONATES

====================  Disposal Considerations  ====================

Waste Disposal Methods:ALLOW GAS TO DISCHARGE AT A SLOW RATE. WASTE GAS
    CAN BE PIPED TO AN APPROVED INCINERATOR TO BURN OFF PROPANE &
    CONVERT CO TO CO2 UNDER CONTROLLED CONDITIONS. RETURN CYLINDER TO
    SUPPLIER. DISPOSE OF IN  ACCORDANCE W/LOCAL, STATE & FEDERAL
    REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.